Desktop Laser Particle Counter Cleanroom With 2.83L Small Flow Rate

Ask Latest Price
Video Channel
Brand Name :KQET
Model Number :KQ-4001
Certification :CE
Place of Origin :China
MOQ :1pc
Payment Terms :T/T
Name :Laser Particle Counter Cleanroom
Sampling Flow Rate :2.83L/min(0.1CFM)±5%
Concentration Error :0.5μm≤±20%FS
Repetition Error :±5%FS
Self-Cleaning Time :≤5min
Particle Size Distribution Error :≤±20%
Particle Size Channels :0.3μm 0.5μm 1.0μm 3.0μm 5.0μm 10.0μm
Price :Negotiation
Packaging Details :Carton
Delivery Time :5 work days
Supply Ability :100 units/month
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Desktop Laser Dust Particle Counter With Small Flow Rate Of 2.83L

1. Product Overview

The KQ-4001 desktop laser dust particle counter with small flow rate of 2.83L is a precision test instrument applied to clean environment cleanliness inspection. It is mainly applied to cleanliness testing and measurement of clean room. The product shell is made of stainless steel, combined with a professional industrial design, the handle is built-in button rear, the first in the industry, simple and atmospheric appearance, the smallest volume and lightest weight in China, the body adopts a 7-inch touch screen, the display of detection data is intuitive, touch operation is simple, comfortable, efficient and convenient. The core sensor is based on the theoretical principle of light scattering, and the particle size detection and particle number counting of suspended particles in the clean environment is achieved through precise photoelectric sensing technology.

The instrument is widely used in pharmaceutical factories, electronics factories, hospital operating rooms, aerospace, precision processing, food industry and other clean scenes, with good stability, high measurement accuracy, atmospheric appearance, light use and other characteristics.

2. Product features

  • Large 7-inch high-definition screen with higher resolution and faster response, allowing users to read cleanliness data intuitively
  • Friendly human-machine interaction, simple and direct operation, reducing user learning costs and improving user experience
  • Compact size, easy to carry, supports desktop / handheld dual-use
  • Real-time flow monitoring, using intelligent algorithms to achieve real-time negative feedback self-adjustment of flow, more accurate detection results
  • 20000 groups of large-capacity data storage, support U disk a key to export PDF files, download data anytime, anywhere
  • Support 400 room point preset function, one key selection, fast sampling
  • Support 20 users management, support password complexity management, support multi-level authority management
  • Support audit trail, log management, queryable, traceable, controllable, in line with FDA 21CFR PART11 specification
  • Support 6 channels/2 channels (0.5um, 5.0um) custom switch
  • Support calibration reminder function, remind users to measure in time to ensure the normal use of the instrument
  • Long life laser source, service life of more than 30,000 hours (need to be calibrated annually)
  • Large-capacity quality lithium battery, longer life, AC and DC dual-use
  • Expandable, with analog access hardware interface, can be external temperature and humidity sensor / wind speed sensor / differential pressure sensor, etc. (optional)

3. Main technical parameters

Particle Size Channels 0.3μm,0.5μm,1.0μm,3.0μm,5.0μm,10.0μm
Sampling Flow Rate 2.83L/min(0.1CFM)±5%
Particle Size Distribution Error ≤±20%
Concentration Error 0.5μm≤±20%FS
Repetition Error ±5%F.S
Self-Cleaning Time ≤5min
Sampling Period User-settable (1 to 9999 seconds)
Sampling Delay User-settable (1 to 999 seconds)
Number of Sampling Times User-settable (1 to 50)
Number of Sampling Points User-settable (2 to 50)
Sampling Mode Upper confidence limit (UCL) measurements, general measurements
Point Presets 400 room point preset, one key selection, fast sampling
Laser Light Source Long-life laser diode with 10-year service life
Vacuum Requirements Built-in miniature real air source
Screen Display 7-inch IPS touch color screen
Printing Method Embedded thermal printing
Charging Power Supply Input AC100-240V/50Hz, Output DC12.6V/2A
Built-in Lithium Battery DC12V/15AH
Battery Life ≥6 hours
Battery Charging Time 2.5 hours
Data Storage 20000 bars
Data Export U disk export + USB communication export, export format PDF
Data Security Management of 20 multiple users, management of password complexity, management of multi-level permissions
Channel Selection 6-channel/2-channel (0.5 5.0um) custom switching
Calibration Reminder Calibration reminder function to remind users of timing and measurement to ensure the normal use of the instrument
Audit Trail Searchable, traceable and controllable, in compliance with FDA 21CFR PART11 specifications
Temperature and Humidity Detection 0~50℃ 0~100%RH (Optional function)
Calibration Specifications JJF1190-2008,GB/T6167-2007
Judgment Criteria cGMP static, GMP dynamic, ISO14644-1
Housing Material 304 stainless steel
Housing Size Length 20cm×width 11cm×height 17cm
Weight 2.2Kg (with battery)
Working Environment Temperature 0~40°C Humidity 10%~90% No condensation
Storage Environment Temperature -10~50°C Humidity 0~90% No condensation